Clipsal CLI755RLPSMA4 - Gen4 Surface Mounted Photoelectric 10 Year Rechargeable Battery Smoke Alarm
$1,103.80
Clipsal's Fire Tek range helps protect the most valuable assets; family, friends and the home. The high-quality, robust electronics of Clipsal smoke alarms are designed for reliability, to ensure early detection and warning from hazardous smoke and fire. It is simple to use and maintain, and one of few on the market carrying the 5 Ticks mark of quality assurance.
Not sure how many Smoke Alarms you require? Refer to the Smoke Alarm Installation & Positioning requirements tables below. Smoke Alarms connected to a home's mains power require a licensed Electrician to install.
Features:
- Photoelectric detection technology for early detection and warning from hazardous smoke and fire.
- Includes surface-mount, low-profile and flush-mounted options.
- Optional mounting bases for wireless interconnect or control of third party devices, with remote test/hush input option.
| Product Range | Fire Tek |
| Device Application | Early detection of smouldering fires and open fires |
| Electronic Sensor Type | Photo-electric sensor |
| Supply | Mains 220-240 V AC 50 Hz |
| Secondary Power Source | Rechargeable lithium battery (sealed in) |
| Battery Life | 10 year(s) |
| Maximum Number of Device Interconnected | 40 for Wired Alarm |
| Type of Installation | Indoor |
| Device Mounting & Support | Surface - Ceiling, Wall |
| Diameter (mm) | 140 |
| Height (mm) | 47 |
| Product Certifications | RCM, SAI, Activfire |
| Standards | ISO 8201, AS 3786:2014, AS/NZS 60950.1, AS/NZS 60065 |
| Mercury free | Yes |
| What's Included In This Package | Clipsal CLI755RLPSMA4 Smoke Alarms & Installation of choice |
| Manufacture Warranty | 18 month(s) |
| Installing Smoke Alarms for Private homes, townhouses and units |
|
Smoke alarms must be installed:
|

| Positioning | Requirement |
| Flat ceiling | Minimum 300mm from the wall |
| Cathedral ceiling | 500mm to 1500mm from the peak |
| Vaulted ceiling | 500mm to 1500mm from the peak & minimum 300mm from exposed joist |
| Suspended ceiling (closed) | Minimum 300mm from the wall |
| Suspended ceiling (open) | Must be mounted on the upper most ceiling & minimum 300mm from the wall |
| Beamed (exposed joist) ceiling | Minimum 300mm from the wall & mounted on the underside of the joist |
| Lean-to ceiling | 500mm to 1500mm from the peak |
| Tray ceiling | 300mm to 500mm from the ceiling & minimum 300mm from the corner of 2 walls. (Only if not practicable to mount a smoke alarm on a ceiling) |
| Wall mount | 300mm to 500mm from the ceiling & minimum 300mm from the corner of 2 walls. (Only if not practicable to mount a smoke alarm on a ceiling) |